CLM400 Cable length meter |
| |
 |
| |
|
The CLM400
is a cable length meter, is useful for technicians on the work
floor. Suitable to measure the cable length, distance to
???split or break???, shorts and for opens. This machine his
measure method deal with the capacitance and resistance of the
cable. Useful is the cable length meter for telecom cables, coax
or two conductor cables. The CLM400 is including with twelve
user-programmable wire settings. Besides is this machine useful
as wire-seeker, through the tone generator including with four
tones in combination with the optional receiver. With a new
definitive cable length with the length between the 30 to 60
meter determine the CLM400 the capacitance and impedance of a
cable. Measure results will be displayed on the LCD-screen. The
auto shutdown gives the battery a longer average life.
|
| |
|
Features |
| |
|
l |
Measures distance to opens and shorts. |
|
l |
Operation modes: mm/mm²/Awg, Telco, Network, Coax, Tone
Generator, and Ohms. |
|
l |
Measures single or dual (pair) conductor length in meters or
feet. |
|
l |
Provides audible indicator for shorted wires. |
|
l |
Large LCD for easier reading in sunlight. |
|
l |
Measures copper or aluminum wires 3.264 to 0.255 mm, 8.366 to
0.051 mm² (8 to 30 Awg). |
|
l |
High voltage protection. |
|
l |
Opens/capacitance measurement 1,500 meter (5,000 feet) at 15 pF/ft. |
|
l |
Shorts/resistance 0-635
Ω. |
|
l |
12
programmable wire settings. |
|
l |
9V
battery operation. |
|
l |
Applications:
- Troubleshoot new or existing telecom and computer lines by
measuring distance to opens.
- Trace wires by generating up to four trace tones with optional
receiver.
- Manage telecom and computer cable inventory by measuring
length on spools.
- Determine if telecom and computer wire length on spools is
adequate. |
|
|
|
Associated Kits with the CLM400: |
|
l |
KP105 High-Powered Field Kit:
TT100 & TG201 in a Corduratm
pouch |
|
|
|
CLM400 Cable length meter Package Contents: |
|
1 |
CLM400
Main unit |
|
2 |
TP76 CLM400 to Banana |
|
2 |
Banana to Alligator clip for the CLM400 |
|
1 |
TP75 BNC M to F female adapter |
|
1 |
TP75 Adapter CLM400 to BNC F |
|
1 |
PC500 Pouch for CLM400 |
|
1 |
Manual |
|
|
Specifications |
|
|
Size: |
3,3
x 7,6 x 15,2 cm |
|
Weight: |
326 gram with battery and test leads |
|
Operating temperature: |
0 to
50°C |
|
Storage temperature: |
-10
to 60°C |
|
Humidity: |
10
to 90%, non-condensing |
|
Battery: |
9V
Alkaline battery |
|
Battery life (standby): |
2,5
year |
|
Cable testing: |
20
hours into 60Ω load
(Note: Smaller resistance loads will result in shorter
battery life) |
|
Cable types: |
Single or
dual conductor, 3,264 to 0,255 mm, 8,366 to 0,051 mm²
(Awg8 - Awg30),
network cabling, coax, and telco |
|
High Voltage Protection: |
120 Volt AC |
| |
| Distance to
Opens/Capacitance: Max 0.082 uf |
| Wire Type: |
Typical Capacitance (per
meter): |
Length: |
Tolerance: |
| Telecom: |
53 |
0 to 1371 m
(0 to 4500 ft) |
- Min. cable length 0.91 m (3
ft.)
- +/-2% + 3 digits LSD |
| Network wire: |
46 |
0 to 1524 m
(0 to 5000 ft) |
- Min. cable
length 0.91 m (3 ft)
- +/-2% + 3 digits LSD |
| Coax: |
67 |
0 to 1066 m
(0 to 3500 ft) |
- Min. cable
length 0.91 m (3 ft)
- +/-2% + 3 digits LSD |
| |
|
Distance to Shorts/Resistance: 0 to 635 Ω |
| mm²: |
Minimum (meters): |
Length: |
Tolerance: |
|
8-5 |
1,5 |
0 to 3047 m
(0 to 9999 ft) |
+/-2% + 3 digits
LSD |
|
3-1,3 |
1,2 |
0 to 3047 m
(0 to 9999 ft) |
+/-2% + 3 digits
LSD |
|
0,8-0,3 |
0,9 |
0 to 3047 m
(0 to 9999 ft) |
+/-2% + 3 digits
LSD |
|
0,2-0,08 |
0,3 |
0 to 3047 m
(0 to 9999 ft) |
+/-2% + 3 digits
LSD |
|
0,05 |
0,3 |
0 to 1792 m
(0 to 5879 ft) |
+/-2% + 3 digits
LSD |
|
LSD: Least Significant Digit |
| |
| Qualified: |
CE, RoHS and
WEEE |
|
|
|
|